      Human Interleukin 2 (IL-2)

      FOR RESEARCH USE ONLY

      Assay range30 pg/ml -1200 pg/ml                   96 determinations

      Purpose

      This kit allows for the determination of IL-2 concentrations in Human serum, cell culture supernates and other biological fluids

       

      Principle of the assay

      The kit assay Human Interleukin 2 (IL-2) level in the sampleuse Purified Human Interleukin 2 (IL-2)antibody to coat microtiter plate wells, make solid-phase antibody, then add Interleukin 2(IL-2) to wells, Combined antibody which With HRP labeled goat anti- Human become antibody - antigen - enzyme-antibody complex, after washing Compley, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of  Human Interleukin 2 (IL-2) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

      Materials provided with the kit

      1

      wash  solution

      20ml×1bottle

      7

      Stopp Solution

      6ml×1 bottle

      2

      HRP-Conjugate reagent

      6ml×1 bottle

      8

      Standard2400pg/ml

      0.5ml×1 bottle

      3

      Microelisa stripplate

      12well×8strips

      9

      Standard diluent

      1.5ml×1bottle

      4

      Sample diluent

      6ml×1 bottle

      10

      Instruction

      1

      5

      Chromogen Solution A

      6ml×1 bottle

      11

      Closure plate membrane

      2

      6

      Chromogen Solution B

      6ml×1 bottle

      12

      Sealed bags

      1

      Specimen requirements

      1.       extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20 to preserve, Avoid repeated freeze-thaw cycles.

      2.       Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.

      Assay procedure

      1.       Dilute and add sample:Dilute Original density Standard as follow table:

      1200 pg/ml

      5 Standard

      150μl Original density Standard+150μl Standard diluent

      600 pg/ml

      4 Standard

      150μl 5 Standard+150μl Standard diluent

      300 pg/ml

      3 Standard

      150μl 4 Standard+150μl Standard diluent

      150 pg/ml

      2 Standard

      150μl 3 Standard +150μl Standard diluent

      75 pg/ml

      1 Standard

      150μl 2 Standard +150μl Standard diluent

      2.add sampleSet blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40μl to testing sample well, then add testing sample 10μl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.

      3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37.

      4.Configurate liquid: 30-fold wash solution diluted 30-fold (or 20-fold) with distilled water and reserve.

      5.washingUncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.

      6.add enzymeAdd HRP-Conjugate reagent 50μl to each well, except  blank well.

      7.incubateOperation with 3.

      8.washingOperation with 5.

      9.colorAdd Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37

      10.Stop the reactionAdd Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color).

      11.assaytake blank well as zero , Read absorbance at 450nm after Adding Stop Solution and within 15min.

      Steps description

      Standard, Sample diluent

       

      Add Standard, Sample diluent, incubate for 30 min at 37.

       

      Wash 5 time,Add HRP-Conjugate reagent, incubate for 30 min at 37.

       

      Wash 5 times,Add Chromogen Solution A and B, incubate for 30 min at 37.

       

      Add Stopp Solution

       

      Read absorbance at 450nm within 15 min

       

      calculate

      Calculate

      Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor, the result is the sample actual density.

      Important notes

      1.       The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.

      2.       washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.

      3.       add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .

      4.       if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.×n×5.

      5.       Closure plate membrane only limits the disposable use, to avoid cross-contamination.

      6.       The substrate evade the light preservation.

      7.       Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.

      8.       All samples, washing buffer and each kind of reject should according to infective material process.

      9.       Do not mix reagents with those from other lots.

       

      Storage and validity

      1Storage  2-8.

      2validity six months.

       

    主站蜘蛛池模板: 无码av在线一本无码| 午夜无码性爽快影院6080| 亚洲一区av无码专区在线观看| 99e久热只有精品8在线直播| 亚洲人成无码网站18禁10| 又黄又爽又色又刺激的视频| 免费高清无码| www.99热| 久久亚洲精品无码爱剪辑 | 日本又色又爽又黄的a片18禁| 成年女人色毛片| 极品少妇高潮到爽| 亚洲日韩精品欧美一区二区| 精品久久久久久成人av| 国产看真人毛片爱做a片| 三级视频兔费看| 国产白嫩护士被弄高潮| 人与嘼交av免费| 成在线人免费视频| 无码色偷偷亚洲国内自拍 | 日韩a片无码毛片免费看| 波多野结衣在线精品视频| 久久香蕉国产线熟妇人妻 | 色婷婷亚洲婷婷八月中文字幕 | 一二三四日本高清社区5| 亚洲一区在线观看尤物| 精品国产久九九| 亚洲 暴爽 av人人爽日日碰| 97久久国产成人免费网站| aⅴ无码视频在线观看| bt天堂新版中文在线地址| 国产精品久久久久人妻无码| 男人和女人高潮做爰视频| 香蕉久久人人97超碰caoproen| 老子午夜理论影院理论 | 国产日韩综合av在线观看一区| 国产老太一性一交一乱| 成人区亚洲区无码区在线点播| 少妇人妻陈艳和黑人教练| 不知火舞私秘?奶头大屁股小说 | 中国猛少妇色xxxxx|